Skip to main content

Hospital visitor and patient WiFi procurement: Healthcare trust RFP checklist

Use this checklist to write a hospital patient and visitor WiFi RFP you can score and test. You will be able to specify minimal-data sign-in, four-layer separation from clinical systems and hospital networks, zone-based filtering, per-device bandwidth caps and HIPAA evidence. You can also write acceptance tests that bidders must price before contract award.

By James KeanPublished
📖 14 min read3,187 words3 worked examples12 key definitions

Part of our core series: Guest WiFi: the complete guide →

Hospital visitor and patient WiFi procurement: Healthcare trust RFP checklist

An NHS patient WiFi tender needs five requirements. Patients and visitors sign in with minimal data, and the network remembers long-stay devices. Patient traffic runs separately, with no route to clinical systems or the Health and Social Care Network. Set filtering per ward, cap bandwidth per device, and require supplier evidence for HIPAA.

What should NHS patient WiFi procurement deliver?

Patients use WiFi for video calls home, streaming and online banking during their stay. Visitors work from the bedside. Outpatients wait in clinics and the ER with nothing else to do.

That same network carries risk for the trust. It shares access points with clinical devices and staff laptops. Anyone in the building can join it, including children. Every sign-in also creates personal data that you are accountable for under CCPA/CPRA.

A good tender turns those tensions into requirements you can test. This guide covers five areas, in the order a network team builds them:

  • Sign-in that asks for little and remembers long-stay patients.
  • Separation from clinical networks and the Health and Social Care Network (HSCN). HSCN is the private network NHS organizations use to reach national clinical services.
  • Filtering matched to adult wards, pediatric wards and waiting areas.
  • Fair bandwidth on busy wards.
  • Evidence for HIPAA. This is the annual self-assessment completed by every organization with access to NHS patient data and systems.

Purple's Guest WiFi platform runs on access points your trust already owns. Purple Access handles patient and visitor sign-in. Purple Shield applies filtering on patient and visitor networks. Purple is live in 80,000+ venues across 90 countries, and handled 440 million logins in 2024 (Purple data). For sector context, see our Healthcare page.

What does the trust need before it goes to tender?

An inventory of the wireless estate

List every controller and access point model by site, with firmware versions. If mergers have left you with more than one vendor, record that as well. Sign-in integration depends on current controller software, so out-of-support firmware belongs on the risk register before the tender goes out.

Purple is hardware-agnostic and works as a cloud overlay on Cisco Meraki, HPE Aruba, Ruckus, Juniper Mist, Ubiquiti UniFi, Cambium, Extreme and Fortinet. If your estate sits on that list, you can specify software on existing hardware rather than a refresh. Why your next WiFi upgrade doesn't need new hardware sets out that reasoning.

A target network design

Agree on the design internally before vendors see it. At minimum, it should include:

  • Separate SSIDs (broadcast network names) for clinical, staff, and patient or visitor traffic.
  • A separate VLAN behind each SSID. A VLAN (virtual LAN) keeps traffic logically apart on shared switches.
  • A dedicated internet breakout for patient traffic, outside HSCN.
  • Firewall rules that deny the patient VLAN any route to internal address ranges.

Governance sign-off

Bring the Information Governance Lead in from day one. Start a data protection impact assessment (DPIA) now. CCPA/CPRA requires one where processing is likely to result in high risk. Sign-in data that places a person in a hospital can meet that test.

Involve the safeguarding lead for children's and behavioral health units. Involve the patient experience team, which hears the complaints when WiFi fails. If the foundation or charity partner wants consent to contact visitors, involve them now rather than after launch.

A named owner for each area

  • Head of Digital: scope, budget, and the evaluation panel.
  • Network Manager: design, integration, and acceptance testing.
  • Information Governance Lead: DPIA, data processing agreement, and HIPAA evidence.

Tenders launched from February 24, 2025 run under current procurement regulations. Write requirements as testable statements, so evaluation scores map cleanly to evidence.

How do you write the RFP requirements, section by section?

Sign-in: what to ask patients and visitors, and what not to ask

Most patient networks use a captive portal. This is the web page a device sees before it reaches the internet. Your RFP should define what that page asks, and what it must never ask.

Require:

  • Minimal data by default. Terms acceptance alone, or an optional email address or cell phone number. Nothing else should be mandatory.
  • Separate flows for patients and visitors. Long-stay patients get a device that stays recognized for the length of their stay. Visitors get a shorter session.
  • Conscious-choice opt-ins. Any request to contact someone, for example by the foundation partner, must sit apart from the terms and start unchecked. The TCPA and CAN-SPAM govern electronic marketing consent.
  • Accessibility. The sign-in page should meet the ADA and Section 508, work with VoiceOver and TalkBack, and offer the main languages your population speaks.
  • Returning-device recognition that survives private addresses. iOS and Android randomize device MAC addresses by default. Ask vendors how they recognize a returning patient's device despite this.

Forbid:

  • Social Security number, date of birth, unit, physician, or medical condition. Sign-in data that ties a named person to a specific unit can reveal health information. That is protected health information under HIPAA and CCPA/CPRA.
  • Personal data from children. Children's online privacy regulation (COPPA) sets 13 as the age of consent for online services. Children's wards should use terms-only sign-in.

Worked scenario: sign-in on a long-stay ward

Situation. A regional hospital runs patient WiFi with four-hour sessions and a mandatory email field. A patient in a senior care ward stays six days and is awake around 16 hours a day.

What was done. The facility specifies remembered devices for the length of an inpatient stay. The email field becomes optional. Visitors keep a four-hour session.

Outcome, by the arithmetic. With four-hour sessions, the patient signs in four times a day, or 24 times across six days. With a remembered device, the patient signs in once. The mandatory data collected drops from one email address per patient to none. This is illustrative arithmetic, but it is the calculation an evaluation panel should ask each bidder to reproduce.

The pattern mirrors hotels, where a guest expects to sign in once per stay. Our Hotels page covers that model.

Keeping patient and visitor traffic apart from clinical systems

Require separation at four layers, and require each to be demonstrated at acceptance.

  1. Radio. Patients and visitors join their own SSID. Staff and clinical devices authenticate with IEEE 802.1X, a standard that checks each device's identity before it joins the network. Use EAP-TLS, which authenticates with certificates rather than passwords.
  2. Switching. The patient VLAN never shares a trunk to clinical segments without firewall inspection.
  3. Routing. Patient traffic breaks out to the internet directly. The firewall denies every internal range and every secure network route.
  4. Client isolation. Patient devices cannot see or reach each other on the same SSID.

Two further points belong in the specification. First, consider WPA3 Enhanced Open, also called OWE (Opportunistic Wireless Encryption). It encrypts traffic on an open network without a password, which protects patients on shared wards. Our guide to WPA3 and per-device keys: what each vendor supports covers support by vendor.

Second, keep medical and facility devices off the patient SSID. Use iPSK (identity pre-shared key, a unique key per device) or 802.1X for devices that cannot run a full login. Every extra SSID also beacons and consumes airtime, so cap the total at three or four per radio.

For staff, Purple SecurePass and Purple's cloud RADIUS service authenticate staff against Microsoft Entra ID, Okta or Google Workspace. RADIUS is the protocol access points use to check credentials with a central server. Revoking a leaver in the identity provider then removes their WiFi access. Purple layers on top of existing infrastructure for sign-in and policy. It does not route clinical traffic. Why is it important to secure a network? a 2026 guide gives the wider security case.

Filtering for wards, children's wards and waiting areas

Set a baseline that applies everywhere patients and visitors connect. Block content on the Internet Watch Foundation (IWF) list of child sexual abuse imagery. Block terrorist content referred by the Counter Terrorism Internet Referral Unit (CTIRU). Healthcare compliance requirements apply to hospitals and health systems. Also block known malware and phishing domains.

Above that baseline, filtering should vary by zone. Purple Shield applies filtering on patient and visitor networks. Write the zone policies below into the tender and ask every bidder to demonstrate them live.

Zone Who connects Block above baseline Allow explicitly Sign-in
Adult inpatient wards Patients, visitors Adult content Health information portals, sexual health and cancer information Remembered for length of stay
Children's and young people's wards Children, parents, caregivers Adult content, gambling, dating, weapons, self-harm promotion Education platforms, video calling, health resources Terms only, no personal data
Mental health inpatient units Patients Adult content, gambling, self-harm and suicide promotion Crisis lines, mental health support pages Device-based, policy agreed with the clinical team
Maternity Parents, birth partners Adult content Pregnancy and baby resources, video calling Remembered for length of stay
Outpatients, ER and waiting areas Mixed public, including children Adult content, gambling Health portals, local transit sites Terms only or optional email, four-hour session

Overblocking is the common failure. Category filters can catch sexual health, breast cancer or eating disorder recovery pages. Require a facility-managed allowlist and a named route for patients to report a wrongly blocked page.

Fair bandwidth on busy wards

Demand on patient networks peaks at visiting hours and in the evening, when patients stream. Without controls, a few heavy devices take most of the capacity. The tender should require four controls:

  • Per-device rate limits on the patient SSID, set separately for upload and download.
  • Airtime fairness, so slow or distant devices cannot monopolize an access point's radio time. Cisco Meraki, HPE Aruba and Ruckus controllers all offer per-client limits and fairness controls.
  • WMM prioritization, based on IEEE 802.11e, so clinical and voice traffic outranks patient streaming on shared radios.
  • A separate internet link for patient traffic, so a busy evening never touches clinical bandwidth.

Worked scenario: evening peak on a 1 Gbps patient link

Situation. An acute healthcare provider runs patient and visitor traffic over a dedicated 1 Gbps internet link. At evening peak, many inpatients stream video at once.

What was done. The provider caps each patient device at 5 Mbps download. Netflix's help center lists 5 Mbps for Full HD and 15 Mbps for 4K.

Outcome, by the arithmetic. Uncapped 4K streams at 15 Mbps fill the 1 Gbps link at 66 devices. Capped at 5 Mbps, the same link carries 200 Full HD streams. The cap triples the number of patients who can watch at once, and nobody drops below Full HD quality.

Ask bidders for per-ward reporting on peak connections and throughput. Purple WiFi Analytics shows when and where patient and visitor networks are busiest. That tells facilities where an extra access point earns its cost.

Evidence for HIPAA Compliance

Patient WiFi touches several security principles. Make the evidence below a tender deliverable, not a favor requested after contract award.

Security principle WiFi evidence Provided by
Asset management Controller and access point inventory, SSID register IT network team
Supply chain Supplier ISO 27001 certificate, Cyber Essentials certificate, data processing agreement Supplier
Identity and access control 802.1X with EAP-TLS for staff, leaver revocation through the identity provider IT and supplier
Data security Assessment, list of sign-in data fields, retention schedule Compliance Lead and supplier
System security Segregation diagram, firewall rule export, penetration test from the patient SSID Network Manager
Security monitoring Authentication and sign-in logs, log retention period, export format Supplier

Purple holds ISO 27001 and Cyber Essentials certification and is CCPA/CPRA compliant. The healthcare provider remains data controller for patient and visitor sign-in data. The data processing agreement should name Purple as processor.

Got questions about your specific setup?

Our team works with venue operators, IT managers, and network engineers across 80,000 venues. Book a 20-minute call and we will show you how others like you solved it.

Guaranteed response within 4 business hours - No commitment required

How do you check the network works before you sign off?

Write the acceptance tests into the tender so bidders price them. Run each test on every site, not one pilot ward.

Separation tests, from a device on the patient SSID:

  • Attempt to reach clinical subnets, management interfaces and secure network addresses. Every attempt should fail.
  • Attempt to reach another patient device on the same SSID. Client isolation should block it.
  • Commission a penetration test from the patient network by an accredited tester.

Sign-in tests:

  • Sign in on iOS, Android, Windows and ChromeOS, with VoiceOver and TalkBack running.
  • Return the next day with the same device. A long-stay patient should connect without a second sign-in.
  • Export the stored record. It should contain only the fields listed in the DPIA.

Filtering and bandwidth tests:

  • Request blocked and allowlisted pages from each zone in the filtering table.
  • Run a speed test on a patient device. It should stop at the configured cap.

Staff tests:

  • Disable a test account in Microsoft Entra ID and confirm the device loses staff WiFi access.

What goes wrong, and how do you fix it?

The sign-in page does not appear

Cell phones detect captive portals by requesting a test page over plain HTTP. If the firewall or DNS blocks that request, no page appears. Allow the sign-in service's domains through the walled garden, the short list of sites reachable before sign-in. Purple's support documentation for your controller lists them.

Long-stay patients keep being asked to sign in

Two causes are common. Session length is set for visitors rather than patients, or the platform identifies devices by MAC address and the phone rotates its private address. Fix the session length per SSID or flow, and confirm how returning devices are recognized.

A clinical device has joined the patient network

Infusion pumps, scanners and facilities sensors sometimes get configured on the easiest network. Move them to iPSK or 802.1X, where each device has its own credential. Then report on unknown devices joining the patient SSID and review the list with clinical engineering.

Filtering blocks legitimate health information

Add the domain to the trust allowlist and record the change. Review the allowlist with the patient experience team each quarter, so recurring complaints become standing exceptions.

Wards slow to a crawl at visiting time

Check per-device caps first, then airtime fairness, then SSID count. If all three are correct and one ward still saturates, commission a predictive survey. That ward may need an extra access point. WiFi networking explained: How it stays secure covers the radio basics behind these checks.

The Privacy Officer cannot answer a subject access request

This happens when nobody knows what the sign-in stores or where. Require a self-serve export by email address or phone number in the request for proposal. Test it at acceptance.

What does it cost, and what does the hospital system get back?

The biggest cost decision is whether the request for proposal assumes new hardware. The table compares the three routes hospital systems typically weigh.

Approach Hardware needed Change on wards Filtering Sign-in data control HIPAA compliance evidence Who it suits
Cloud overlay on existing access points (Purple) None: runs on installed Cisco Meraki, HPE Aruba, Ruckus, Juniper Mist, Ubiquiti UniFi, Cambium, Extreme or Fortinet Configuration change on existing controllers Purple Shield on patient and visitor networks Hospital sets fields, opt-ins and retention Supplier certificates, logs and data processing agreement Healthcare systems with in-support wireless estates
Managed service with supplier-owned access points A second set of access points on every ward Physical install, ward by ward Supplier's own filter Defined by the supplier contract Supplier certificates, plus a second network to document Healthcare systems with no wireless estate on wards
Controller's built-in splash page None Configuration change on one vendor Separate product to buy Terms acceptance only, per vendor Healthcare system assembles evidence itself Single-vendor sites needing terms acceptance only

Purple sells three plans: Connect, Capture and Engage. SecurePass, Verify and Shield are add-ons. Purple quotes each healthcare system against the plan, sites and add-ons in scope. That makes the RFP's site list and zone table the inputs that set the price.

What the healthcare system gets back is measurable. The worked scenarios show one sign-in per stay instead of 24, and three times as many concurrent streams per link. The HIPAA compliance mapping turns six core framework principles into supplier deliverables. Conscious-choice opt-ins give the hospital foundation consented first-party data rather than a scraped mailing list.

Frequently asked questions

Can Purple run on the access points our healthcare system already owns?

Yes, Purple runs as a cloud overlay on access points from Cisco Meraki, HPE Aruba, Ruckus, Juniper Mist, Ubiquiti UniFi, Cambium, Extreme and Fortinet. Your hospital system keeps its controllers and wiring. Purple Access adds patient and visitor sign-in, and Purple Shield adds filtering, through configuration on the existing estate. Check that controller firmware is in support before go-live, because sign-in integration depends on current controller software.

How is Purple licensed for a healthcare system?

Purple licenses by plan, with optional security add-ons. The plans are Connect, Capture and Engage. SecurePass, Verify and Shield are add-ons. Purple quotes each healthcare system against the plan, the sites in scope and the add-ons chosen. Your RFP's site list and zone policies therefore drive the price. Because Purple runs on existing access points, the quote does not include new ward hardware.

Will patient WiFi data stay compliant with CCPA/CPRA and HIPAA?

Yes, when the RFP sets the right rules. Purple holds ISO 27001, SOC 2 Type II, and Cyber Essentials certification and is CCPA/CPRA and HIPAA compliant. Your healthcare system stays data controller and signs a business associate agreement with Purple as processor. Collect the minimum: terms acceptance or an optional contact detail. Never collect Social Security number, medical record number, ward or condition, which can turn sign-in data into protected health information (PHI).

Can patient WiFi reach our clinical systems or internal networks?

No, not when the network follows the design in your RFP. Patient and guest traffic runs on its own SSID and VLAN, breaks out directly to the internet and is denied every internal route at the firewall. Client isolation stops patient devices reaching each other. Purple handles sign in and policy on that network. It does not route clinical traffic. Prove all of this with a penetration test at acceptance.

Can we move from our current patient WiFi provider without a gap in service?

Yes, you can run both side by side during cutover. Configure Purple on a new patient SSID alongside the existing one, test it on a pilot unit, then roll unit by unit. Retire the old SSID once every site passes acceptance. Because Purple uses your existing access points, no unit needs a hardware swap, and patients see a change of sign in page rather than an outage.

Why not use our controller's built-in splash page instead?

Purple goes further than a built-in splash page for healthcare organizations that need more than terms acceptance. Built in pages typically cover terms on one vendor's hardware. Purple runs one sign in across mixed estates, remembers long-stay patients, records conscious choice opt-ins and applies Purple Shield filtering per network. It also supplies the logs, certificates and data processing agreement your Information Governance Lead needs for HIPAA compliance.

What WiFi evidence does HIPAA compliance need?

Compliance requirements call for evidence that patient WiFi is segregated, governed and supplied securely. Map it to the security control principles behind healthcare compliance. Provide an access point inventory, a segregation diagram and firewall rule export, and a penetration test from the patient SSID. Add the DPIA, the supplier's ISO 27001 and Cyber Essentials certificates, the data processing agreement, and authentication logs with a stated retention period.

Key Definitions

Captive portal

A web page presented to a device on an open network before internet access is granted. Cell phones detect it by requesting a test page over plain HTTP, so the walled garden must allow the sign-in service's domains.

The sign-in page is where the RFP sets what patients and visitors are asked for. It decides whether the hospital system collects minimal data or drifts into special category data under CCPA/CPRA.

Health Information Network

The private network infrastructure healthcare organizations use to exchange clinical data and access enterprise systems securely.

Patient and visitor traffic must never have a route to internal clinical networks. The RFP should require a firewall that denies every clinical network route and a penetration test from the patient SSID to prove it.

HIPAA Compliance Framework

The legal and regulatory baseline required for any organization processing or managing infrastructure in environments with access to protected health information (PHI).

Patient WiFi touches asset management, supply chain, identity, data security, system security and monitoring evidence. Making that evidence a supplier deliverable avoids chasing it after award.

NIST Cybersecurity Framework (CSF)

The cybersecurity framework of objectives and principles, such as asset management, supply chain, identity and access control and security monitoring, used to assess the security of essential services.

The HIPAA guidelines for health systems now map to security controls. The RFP's evidence table should name which control each WiFi artifact satisfies and who provides it.

IEEE 802.1X

The IEEE standard for port-based network access control. It uses the Extensible Authentication Protocol between device, access point and an authentication server to check each device's identity before it joins the network.

Staff and clinical devices should authenticate with 802.1X rather than share the patient SSID. Terminated employee revocation through the identity provider then removes WiFi access, which feeds security evidence.

EAP-TLS

An Extensible Authentication Protocol method, defined in IETF RFC 5216, that authenticates both client and server with X.509 certificates instead of passwords.

The guide recommends EAP-TLS for staff on 802.1X. Certificates remove shared passwords on hospital floors and give the health system evidence of strong identity and access control.

RADIUS

Remote Authentication Dial-In User Service, specified in IETF RFC 2865, the protocol access points and controllers use to send credentials to a central server for an accept or reject decision.

Purple's cloud RADIUS service checks staff against Microsoft Entra ID, Okta or Google Workspace, so disabling an account in the identity provider revokes staff WiFi access.

VLAN

A virtual LAN as defined in IEEE 802.1Q, which tags Ethernet frames so traffic stays logically separate on shared switches and trunks.

Each SSID needs its own VLAN. The patient VLAN must never share a trunk to clinical segments without firewall inspection, which is the switching layer of the separation requirement.

WPA3 Enhanced Open (OWE)

Opportunistic Wireless Encryption, specified in IETF RFC 8110, encrypts traffic between each device and the access point on an open network without a password.

OWE protects patients in shared rooms from eavesdropping while keeping a password-free sign-in. Check support by access point vendor before writing it into the specification.

iPSK (identity pre-shared key)

A per-device pre-shared key approach in which each device receives its own WPA2 or WPA3 passphrase, mapped to a policy or VLAN by the authentication server.

Infusion pumps, scanners and facilities sensors that cannot run a full 802.1X login should use iPSK, which keeps them off the patient SSID and gives each device its own credential.

WMM prioritization

WiFi Multimedia, a traffic prioritization scheme based on the IEEE 802.11e quality of service amendment, which assigns voice, video, best effort and background traffic to separate access categories.

On shared radios, WMM lets clinical and voice traffic outrank patient streaming during visiting hours and in the evening peak.

Data protection impact assessment (DPIA)

An assessment required under CCPA/CPRA where processing is likely to result in high risk to individuals, describing the processing, its necessity and the measures that address the risks.

Sign-in data that places a person in a hospital can meet the high-risk test. The DPIA defines the permitted data fields, which acceptance testing then checks against the exported record.

Worked Examples

A community hospital runs patient WiFi with four-hour sessions and a mandatory email field. A patient on a geriatric care unit stays six days and is awake around 16 hours a day. How should the RFP change sign-in?

The healthcare system specified remembered devices for the length of an inpatient stay and made the email field optional. Visitors kept a four-hour session. With four-hour sessions, the patient signed in four times a day, or 24 times across six days. With a remembered device, the patient signs in once. Mandatory data collected drops from one email address per patient to none, which reduces risk under CCPA/CPRA. The arithmetic is illustrative, but an evaluation panel should ask every bidder to reproduce it and explain how they recognize returning devices despite randomized MAC addresses.

A hospital system carries patient and visitor traffic over a dedicated 1 Gbps internet link. At evening peak, many inpatients stream video at once and the link saturates. What bandwidth control should the RFP require?

The hospital capped each patient device at 5 Mbps download, the rate Netflix lists for Full HD. Uncapped 4K streams at 15 Mbps fill the 1 Gbps link at 66 devices. Capped at 5 Mbps, the same link carries 200 Full HD streams. The cap triples the number of patients who can watch at once, and nobody drops below Full HD. The RFP also required airtime fairness, WMM prioritization and a separate patient internet link, plus per-unit reporting on peak connections and throughput so facilities can see where an extra access point earns its cost.

During acceptance, the network team finds infusion pumps and facilities sensors connected to the patient SSID because it was the easiest network to configure. How should the hospital fix this and stop it recurring?

The hospital moved each device to iPSK or IEEE 802.1X, so every device has its own credential and sits on its own segment rather than the open patient network. It then set up reporting on unknown devices joining the patient SSID and reviews that list with clinical engineering. This keeps clinical traffic away from a network anyone in the building can join. It also caps the SSID count at three or four per radio, because every extra SSID beacons and consumes airtime that patients and clinical devices share.

Frequently asked questions

Can Purple run on the access points our hospital system already owns?

Yes, Purple runs as a cloud overlay on access points from Cisco Meraki, HPE Aruba, Ruckus, Juniper Mist, Ubiquiti UniFi, Cambium, Extreme and Fortinet. Your health system keeps its controllers and wiring. Purple Access adds patient and visitor sign-in, and Purple Shield adds filtering, through configuration on the existing estate. Check that controller firmware is in support before go-live, because sign-in integration depends on current controller software.

How is Purple licensed for a hospital network?

Purple licenses by plan, with optional security add-ons. The plans are Connect, Capture and Engage. SecurePass, Verify and Shield are add-ons. Purple quotes each health system against the plan, the sites in scope and the add-ons chosen. Your RFP's site list and zone policies therefore drive the price. Because Purple runs on existing access points, the quote does not include new ward hardware.

Will patient WiFi data stay compliant with CCPA/CPRA and HIPAA?

Yes, when the RFP sets the right rules. Purple holds ISO 27001 and SOC 2 Type II certification and is CCPA/CPRA compliant. Your health system stays data controller and signs a data processing agreement with Purple as processor under the CCPA/CPRA. Collect the minimum: terms acceptance or an optional contact detail. Never collect Social Security number, medical record number, ward or condition, which can turn sign-in data into protected health information.

Can patient WiFi reach our clinical systems or internal network?

No, not when the network follows the design in your RFP. Patient and visitor traffic runs on its own SSID and VLAN, breaks out directly to the internet and is denied every internal network route at the firewall. Client isolation stops patient devices reaching each other. Purple handles sign-in and policy on that network. It does not route clinical traffic. Prove all of this with a penetration test at acceptance.

Can we move from our current patient WiFi provider without a gap in service?

Yes, you can run both side by side during cutover. Configure Purple on a new patient SSID alongside the existing one, test it on a pilot unit, then roll out unit by unit. Retire the old SSID once every site passes acceptance. Because Purple uses your existing access points, no unit needs a hardware swap, and patients see a change of sign-in page rather than an outage.

Why not use our controller's built-in splash page instead?

Purple goes further than a built-in splash page for health systems that need more than terms acceptance. Built-in pages typically cover terms on one vendor's hardware. Purple runs one sign-in across mixed estates, remembers long-stay patients, records conscious-choice opt-ins and applies Purple Shield filtering per network. It also supplies the logs, certificates and data processing agreement your Information Governance Officer needs for HIPAA compliance.

What WiFi evidence does HIPAA need?

The audit needs evidence that patient WiFi is segregated, governed and supplied securely. Map it to HIPAA security rule principles. Provide an access point inventory, a segregation diagram and firewall rule export, and a penetration test from the patient SSID. Add the Business Associate Agreement (BAA), the supplier's ISO 27001 and SOC 2 Type II certificates, the data processing agreement, and authentication logs with a stated retention period.

Got questions about your specific setup?

Our team works with venue operators, IT managers, and network engineers across 80,000 venues. Book a 20-minute call and we will show you how others like you solved it.

Guaranteed response within 4 business hours - No commitment required