Passer au contenu principal

Estimateur de points d'accès et de couverture de site

Calculez le nombre de points d'accès sans fil, de commutateurs et le budget PoE requis pour votre site.

Estimez vos besoins en points d'accès

Quick venue presets

1. Venue area size

Square feet

2. Structural layout & wall material

Select wall type to factor in RF signal attenuation loss.

3. Client device density

Estimate client density in peak usage areas.

Approx. 1 device per 50 sq ft

4. Bandwidth activity profile

Select bandwidth demand per active device.

5. WiFi hardware generation

Select the WiFi standard of planned access points.

Current enterprise standard with OFDMA and MU-MIMO for dense client environments.

Recommended hardware deploymentCoverage-driven limit
4Access Points

Coverage signal calculation requires 4 APs for 7500 sq ft. High-density capacity calculation requires 3 APs to serve 150 concurrent client devices using WiFi 6 / 6E. Final recommendation: 4 APs.

Estimated Active Clients150 devices
Total Bandwidth Demand0.75 Gbps
PoE Power Budget (20% Headroom)123 W (PoE+ (802.3at))
Recommended Switch8-port PoE Switch

Hardware vendor deployment notes

Cisco MerakiDeploy MR36/MR46 for standard density, or MR56/CW9166 for high-density environments. Pair with MS120 or MS225 series PoE switches.
HPE Aruba NetworksDeploy AP-515 or AP-635 access points with CX 6100 switches. Set switch port power allocation to Class 4 to avoid smart power throttling.
Ruckus & Juniper MistDeploy Ruckus R550/R750 or Mist AP43/AP45 for high RF interference immunity and automated AI channel optimization.
Expert Site Survey & RF Audit

Get a custom WiFi site survey & AP placement plan

Planning a physical rollout? Speak with a Purple wireless network architect to receive a custom RF attenuation report, heat map simulation, and hardware vendor discount review.

Understanding signal attenuation and capacity limits

Wireless networks are constrained by both physical RF coverage and client device capacity limits. In large open spaces, a single high-power access point can project a signal over a wide radius, but a high concentration of connected smartphones and laptops will saturate radio channels long before signal coverage degrades. This calculator models both constraints simultaneously and recommends the higher access point count to eliminate network congestion.

Planification précise de la capacité réseau

La planification de la couverture sans fil nécessite de modéliser les obstacles physiques, la densité d'utilisateurs et les besoins en bande passante des applications. Ce calculateur vous aide à estimer l'équipement requis pour un réseau invité ou d'entreprise haute performance.

Principaux paramètres modélisés

  • Atténuation du signal à travers les cloisons sèches, la brique, le verre et les murs en béton.
  • Limites de densité d'appareils pour les bureaux standards, le secteur hôtelier à haute densité et les stades.
  • Budgets d'alimentation Power over Ethernet (PoE) globaux et exigences en ports de commutateur.

Signal attenuation benchmarks by building material

Radio frequency signals degrade as they penetrate structural barriers. Use these attenuation values to refine coverage estimates when deploying access points across multi-room facilities.

Building materialFrequency bandSignal loss (dB)Typical coverage radius
Drywall / Office Partition2.4 GHz / 5 GHz1.5 - 3 dB2,000 - 3,000 sq ft (180 - 280 sq m)
Clear Window Glass2.4 GHz / 5 GHz2 - 4 dB2,000 - 2,500 sq ft (180 - 230 sq m)
Solid Brick Wall2.4 GHz / 5 GHz / 6 GHz6 - 10 dB1,000 - 1,400 sq ft (90 - 130 sq m)
Reinforced Concrete / Lift Shaft2.4 GHz / 5 GHz / 6 GHz12 - 18 dB600 - 900 sq ft (55 - 85 sq m)

Power over Ethernet (PoE) switch planning

Modern WiFi 6, 6E, and WiFi 7 enterprise access points feature multi-gigabit uplinks and Bluetooth radios that require high power draw from network switches. Matching access points with the correct PoE standard prevents random access point reboots during peak client loads.

PoE (802.3af)Up to 15.4W per portSufficient for legacy 802.11ac (WiFi 5) indoor access points and basic IP phones.
PoE+ (802.3at)Up to 30.0W per portStandard requirement for WiFi 6 and 6E dual-radio access points (such as Cisco Meraki MR46 and Aruba AP-515).
PoE++ (802.3bt Class 5)Up to 45.0W - 60.0W per portRequired for high-power WiFi 7 access points, outdoor stadium APs, and multi-radio 4x4 / 8x8 setups.
FAQ

Questions fréquentes sur la planification des points d'accès WiFi

Quelle surface un point d'accès WiFi couvre-t-il ?

Dans les environnements intérieurs ouverts avec des cloisons sèches ou en verre, un point d'accès d'entreprise standard couvre entre 1 500 et 3 000 pieds carrés (140 à 280 mètres carrés). Dans les configurations de bâtiments denses avec des murs en briques pleines ou en béton, la couverture effective est réduite à une surface de 800 à 1 200 pieds carrés par point d'accès en raison de l'atténuation RF.

Comment calculer la densité des points d'accès pour les sites à haute densité ?

Le calcul des points d'accès à haute densité donne la priorité à la capacité de clients simultanés plutôt qu'à la zone de couverture physique. Prévoyez 1 point d'accès pour 15 à 30 appareils actifs dans les environnements à forte demande de streaming (comme les stades ou les auditoriums), et 1 point d'accès pour 40 à 50 appareils pour un usage standard de bureau ou de café.

Quelle est la différence entre une planification d'AP basée sur la couverture et celle basée sur la capacité ?

La planification basée sur la couverture calcule les points d'accès en fonction de l'espace physique et de la portée du signal RF afin d'éliminer les zones mortes. La planification basée sur la capacité calcule les points d'accès en fonction du nombre total d'appareils clients connectés et du débit de bande passante requis par appareil. Les conceptions d'entreprise retiennent toujours la plus élevée de ces deux valeurs.

Quel budget de puissance de commutateur PoE est requis pour les points d'accès WiFi 6 et WiFi 7 d'entreprise ?

Les points d'accès WiFi 5 standards utilisent le PoE (802.3af, jusqu'à 15,4 W par port). Les points d'accès WiFi 6 et 6E d'entreprise nécessitent le PoE+ (802.3at, jusqu'à 30 W par port) pour alimenter les radios multi-gigabit et les radios Bluetooth LE. Les points d'accès WiFi 7 avancés dotés de radios MU-MIMO 4x4 ou 8x8 peuvent nécessiter le PoE++ (802.3bt, jusqu'à 60 W par port).

Comment les matériaux des murs affectent-ils la portée du signal WiFi ?

Les cloisons sèches provoquent une atténuation minimale du signal (perte de 1,5 à 3 dB), la brique pleine provoque une atténuation moyenne (perte de 6 à 10 dB) et le béton armé ou les cages d'ascenseur provoquent une forte atténuation (perte de 12 à 18 dB). Une forte atténuation réduit considérablement la zone de couverture des points d'accès.

Deploying guest WiFi across your estate?

Calculating AP quantities is the first step. Purple integrates with Cisco Meraki, HPE Aruba, Ruckus, and Juniper Mist to deliver captive portal login, marketing automation, and location analytics.

Book a 20-min demo
Free Desktop App

Netforge Network Multi-Tool

Run offline network health checks, path analysis, and latency diagnostic scans directly from your desktop.

Download Multi-Tool